Interobserver agreement and intraobserver reproducibility of the subjective determination of glaucomatous visual field progression.
Tanna Angelo P, Bandi Jagadeesh R, Budenz Donald L, Feuer William J, Feldman Robert M, Herndon Leon W, Rhee Douglas J, Whiteside-de Vos Julia
AI Summary
Glaucoma experts showed good intraobserver visual field progression reproducibility, but only moderate interobserver agreement, which GPA data did not improve, highlighting subjective interpretation challenges.
Abstract
Purpose
To determine the extent of interobserver agreement and intraobserver reproducibility of the subjective determination of visual field progression with achromatic automated static perimetry in eyes with glaucoma, and to determine the impact of access to Glaucoma Progression Analysis (GPA) data on interobserver agreement.
Design
Retrospective, observational case series.
Participants
Five glaucoma subspecialists from 5 different academic medical centers.
Methods
Five visual field tests from each of 100 eyes of 83 patients being monitored for glaucoma were retrospectively identified and subjectively and independently evaluated by the 5 glaucoma subspecialists. Each set of visual fields was classified regarding progression as "none," "questionable," "probable," or "definite." More than 1 month later, the same expert observers reevaluated the same sets of visual field tests to allow determination of intraobserver reproducibility. A final subjective evaluation regarding progression was performed 3 months later, at which time the expert observers had access to the GPA printout.
Main outcome measures
The level of interobserver agreement and intraobserver reproducibility was estimated using kappa statistics on the raw classification data and also on dichotomized data in which "none" and "questionable" progression were reclassified together as nonprogressed and " probable" and "definite" were reclassified as progressed.
Results
Intraobserver reproducibility was good to excellent (kappa = 0.62-0.78) for the raw data and moderate to good (kappa = 0.58-0.71) for the dichotomized data. Interobserver agreement was moderate (kappa = 0.45; 95% confidence interval [CI], 0.35-0.55) for the raw classification data and also for dichotomized data (kappa = 0.55; 95% CI, 0.46-0.64). Access to the GPA printout did not significantly change the level of interobserver agreement.
Conclusions
Five glaucoma experts had good to excellent reproducibility of the determination of visual field progression compared with earlier evaluation of the same field sets. Agreement among the experts with each other was only moderate, and did not improve when each had access to GPA results. .
MeSH Terms
Shields Classification
Related Articles5
A Hybrid Deep Learning-Based Approach for Visual Field Test Forecasting.
Cohort StudyRepeatability of Online Circular Contrast Perimetry Compared to Standard Automated Perimetry.
Observational StudySystematic Underestimation of Visual Sensitivity Loss on Microperimetry: Implications for Testing Protocols in Clinical Trials.
Clinical TrialEvaluation of the Consistency of Glaucomatous Visual Field Defects Using a Clustered SITA-Faster Protocol.
Cross-Sectional StudyVisual fields in glaucoma: Where are we now?